G. Theodor Freese GmbH
Aufgenommen im Lexikon der deutschen Familienunternehmen 2009 Bremer Umweltpreis 2003
Deutsch Deutsch
Home / Shipbuilding / Services & Products / Insulating ship floors  
 

Documentation

 

 Technical data as pdf-file
 Show approvals



Acrobat Reader downloaden


IMPORTANT PRODUCT-SPECIFIC DETAILS

 

Preparation of Substructure:

Anchoring clips on deck required!

All deck areas have to be treated with a stable intact 2 comp.EP-shopprimer fast to saponification, which has to be treated with one coat TEFROTEX® SF BONDING COAT.

Other deck types upon request.


Fire Rating:

TEFROLITH® FTG-35 complies with SOLAS 1974 and IMO Resolution A 754 (18) / A 799 (19), FTP-Code Part 1 and Part 3.

Zum Anzeigen der Dokumente benötigen Sie den Adobe Acrobat Reader
Insulating Ship-Floor for A-class 60 divisions
Insulating mortar-system also for wet areas, requires a weight distribution layer as final layer which is approved as not readily ignitable.

Properties:

  • Non-combustible, A-60 rating, (min. 35 mm)
  • low weight
  • not self-levelling, formation of slope possible

TECHNICAL DATA


Installation thickness:


FTG-35 Insulating coat


mind. approx. 35 mm (A-60)

Density:


FTG-35 Insulating coat
+ Toplayer



approx. 0,80 kg/m²/mm

Strengths:


FTG-35 insulating coat
- measurements based on
4 x 4 x 16 cm prisms -
after 28 days
compressive strength:
tensile strength:

 






approx. 7 N/mm²
approx. 2 N/mm²

K-value:


FTG-35 + toplayer


2,30 W/m² • K

 

Your contact

German shipbuilding

Mr Joerg Buchholz
Mr Olaf Henssen
Mr René Noelle

Phone +49 (0)421 / 396 08-0 
Fax +49 (0)421 / 396 08-399


Export

Mr Joerg Buchholz
Mr Wolfgang Moewes

Mr Oliver Remmers
Mrs Heike Winkelmann
Mrs Susanne Boll

Phone +49 (0)421 / 396 08-0 
Fax +49 (0)421 / 396 08-399


 
© 2012 G. Theodor Freese GmbH & Co. KG  ·   Imprint Home    Contact    Top