IMPORTANT PRODUCT-SPECIFIC DETAILS

 

Preparation of Substructure:

All deck areas have to be treated with a tragfähig intact shopprimer, which has to be treated with one coat TEFROTEX® SF BONDING COAT.

Other deck types upon request.

 

Fire Rating:

TEFROTEX® SF complies with teh requirements of FTP-Code Part 1, 5 and Part 6.

Zum Anzeigen der Dokumente benötigen Sie den Adobe Acrobat Reader
Subfloor for floor coverings in accommodation, not for wet areas

 

Properties:

  • one coat, jointless
  • self levelling
  • very good adhesion to pretreated steel-, aluminium and galvanized deck surfaces
  • high surface strength
  • very fast, almost tension-free hardening
  • high strength at an early stage
  • open for foot traffic after 3 hours (20°C)
  • ready for use after 12 hours (20°C)
  • ready to obtain all kinds of floor coverings after 24 hours (20° C)
These characteristics are independent of the thickness of coat laid

TECHNICAL DATA


Thickness:


1 - 10 mm (FTPC Part 5) 
1 - 30 mm (FTPC Part 6)

Density:


approx. 1,8 kg/m²/m

Strengths:


- on 4 x 4 x 16 cm prisms -
after 28 days
Compressive strength: 
tensile strength:

 




approx. 30 N/mm²
approx. 8 N/mm²

 

 

Approved according to

FTPC Part 1 as part of an

A-60-construction

 

Density:


approx. 2,0 kg/m²/m        

Strengths:


- on 4 x 4 x 16 cm prisms -
after 28 days
Compressive strength: 
tensile strength:

 




approx. 26 N/mm²
approx. 8 N/mm²


 


 

Your contact

German shipbuilding

Mr Joerg Buchholz
Mr Olaf Henssen
Mr René Noelle

Phone +49 (0)421 / 396 08-0 
Fax +49 (0)421 / 396 08-399


Export

Mr Joerg Buchholz
Mr Wolfgang Moewes

Mr Oliver Remmers
Mrs Heike Winkelmann
Mrs Susanne Boll

Phone +49 (0)421 / 396 08-0 
Fax +49 (0)421 / 396 08-399


 
© 2012 G. Theodor Freese GmbH & Co. KG  ·   Imprint Home    Contact    Top